LT1060
Features
- Measuring ranges from 0.5 mH2O to 50 mH2O
- Gauge pressure
- Accuracy: ±0.5%FSO(Typ.), ±0.35%FSO
- Calibrated and temperature compensated
- Ceramic sensor
- PP,PVDF & PTFE housing
- Output 4...20mA, I2C, MODBUS, HART and others
Application
- Rain spillway basin
- Level measurement
- Aggressive media level measurement
- Sewage treatment
Technical Data
Pressure range | 0.5mH2O...50mH2O |
Accuracy | ±0.35%FS, ±0.5%FS |
Output signal | 0…5VDC/0.5…4.5VDC/0...10VDC/4...20mA/RS485/IIC |
Operating temperature | 0 to 50°C |
Housing | PP/PVDF/PTFE |
Cable | PUR/PE/PTFE cable with air tube |
Diaphragm material | Ceramic 96%Al2O3 |